  • Glentronics BWSP 1730-Gallons Per Hour Basement Watchdog Special Back-Up Sump Pump
Features
  • Basement watchdog special battery back up sump pump system.
  • Switches to battery power when ac power fails.
  • Begins pumping immediately when water volume exceeds main pump capacity.
  • Automatic recharge, battery monitor, pumps 1730 gallons per hour to 10 ft.
  • Totally submersible, non-corrosive pump housing.
  • Alarm system sounds when battery needs water.
  • Battery is old, battery is discharged, battery cable is loose, power is out & pump was activated.
  • Battery not included, 7.5 hour run time deep cycle battery.
  • Dimension - 17.5 x 10.25 x 14.5 in.
  • Item weight - 11.95 lbs.

  • Pumps 2,500 gph at 10-Feet. of li-Feet and 1730 gph at 0-Feet. of li-Feet
  • User-friendly control panel lights up with a warning and describes what to do for easy maintenance
  • A sensor monitors battery fluid levels for increased piece of mind
  • Includes controller, charger, dual float switch, pump and battery box (battery sold separately)
  • Compact pump can be installed even in small or narrow sump pits

Write a review

Note: HTML is not translated!
    Bad           Good

Glentronics BWSP 1730-Gallons Per Hour Basement Watchdog Special Back-Up Sump Pump

  • Brand: Glentronics
  • Product Code: BWSP
  • Availability: In Stock


Related Products

Basement Watchdog battery 24EP6

Basement Watchdog battery 24EP6

Features6 hour.140a, deep cycle sump pump emergency battery...

Glentronics BWD-HWA Basement Watchdog Water Sensor and Alarm

Glentronics BWD-HWA Basement Watchdog Water Sensor and Alarm

Water damage is one of the main ways that the value of a hom..

Glentronics BWC1 Basement Watchdog Dual Float Sump Pump Switch with Controller

Glentronics BWC1 Basement Watchdog Dual Float Sump Pump Switch with Controller

Features2 floats provide added protectionProtective cage pre..

Dynamic Head

The effect of the Earths gravity on the "lift" or head pressure is fairly simple; for every vertical foot of distance the pump moves the water you are adding one foot of head pressure so the ratio is a 1:1 ratio. The effects of the friction, caused by water as it travels through your hose or pipes, on the total head pressure is a little more difficult to calculate especially as there are slight variations in pipe friction in different hose materials and the smoothness of the inner bore. Basically. for every ten feet of pipe through which the water has to travel travel horizontally will contribute 1 foot of head height; the ratio of the pipe friction loss is a 10:1 ratio.

Plumbing fixtures and bends and corners in your hose also increase the total head you must calculate to ensure the proper final volume from your pump. Every corner with a 90 degree elbow in your plumbing will add 1 foot of head pressure  with a 1:1 ratio. 45 degree elbows, tees and even insert couplers can all have an impact on the final flow.

If you install a pump 40 feet away from the top of your waterfall which is 6 feet above the pump and the tubing is a single run of 40 feet horizontally then you add 4 feet of head for the tubing length (the 10:1 ratio) to the 6 foot differnetial between the pump location and the final height of the waterfall so your final total dynamic head calculation would be 10 feet. This means your final volume of water flow in this water feature or application would be the volume of flow on the performance curve that equaled the gallons per hour at 16 feet. This volume will certainly be much less than the initial volume the pump can move at an open flow or a zero head.

If in the above example your 40 feet of horizontal tubing run also required 3 elbows of 90 degrees then an additional 3 feet of theoretical head would be added and your final flow result would be at 19 feet on the performance curve of the pump. In this example you would want to choose a pump that has the desired GPH rating at 9 feet of head pressure.  Tubing size is also an important factor in accounting for head pressure loss, in general you should never reduce the diameter of the tubing below what the output size of the pump is, this will drastically increase head pressure, and reduce pump performance.  For maximum pump performance, using the largest tubing that is practical is the best choice. A best practice is to use a hose with an inner diameter that is the same as your pumps outlet fitting.