Tetra 1 1/4 in ID Pond Tubing easily connects to pumps, bio-filters, UV clarifiers, waterfall filters and other water features. Tubing will not crimp or collapse and can be buried to conceal.

  • Connects to pumps, bio-filters, UV clarifiers, waterfall filters and other water features
  • Will not crimp or collapse
  • Can be buried to conceal
  • 1 1/4 inch diameter by 20 foot length

Write a review

Note: HTML is not translated!
    Bad           Good

TetraPond Pond Tubing, 1-1/4-Inch by 20-Feet

  • Brand: TetraPond
  • Product Code: 19737
  • Availability: 20
  • $33.47



Related Products

Little Giant 566409 WGP-65-PW Premium Submersible Pond Pump, 1900-Gallons Per Hour

Little Giant 566409 WGP-65-PW Premium Submersible Pond Pump, 1900-Gallons Per Hour

1900 GPH @ 1 Feet head, Voltage: 115, 1/8 horsepower, Unique..

$198.38 $198.57

Laguna Max-Flo 2900 Electronic Waterfall & Filter Pump

Laguna Max-Flo 2900 Electronic Waterfall & Filter Pump

Laguna Max-Flo Waterfall/Filter Pump , Is A High Performance..

$369.99 $523.81

Tetra Pond Water Garden Pump, 1900 GPH

Tetra Pond Water Garden Pump, 1900 GPH

Lawn And Garden 1900 Gph Power Waterfalls, Filters And Fount..

$172.04 $204.00

United Pet Tetra Water Garden Pump 1900Gph

United Pet Tetra Water Garden Pump 1900Gph

Pet SuppliesPet Supply..

$191.73

Little Giant WGP-80-PW 3500 GPH Dual Discharge Waterfall Pump, 673 Watts

Little Giant WGP-80-PW 3500 GPH Dual Discharge Waterfall Pump, 673 Watts

Ideal for use in waterfall and stream applications, this pow..

$243.24 $246.00

Laguna Max-Flo 4280 Electronic Waterfall and Filter Pump for Ponds Up to 8560-Gallon

Laguna Max-Flo 4280 Electronic Waterfall and Filter Pump for Ponds Up to 8560-Gallon

Waterfall and Filter Pump, Maximum Flow Rate 4280 U.S. GPH, ..

$409.99

Laguna Max-Flo 2900 Electronic Waterfall and Filter Pump for Ponds Up to 5800-Gallon

Laguna Max-Flo 2900 Electronic Waterfall and Filter Pump for Ponds Up to 5800-Gallon

MAX-FLO WATERFALL & FILTER. High performance solids handling..

$369.99

Danner Mfg Company 12315 18-Inch by 24-Inch Pond Pump Bag Small

Danner Mfg Company 12315 18-Inch by 24-Inch Pond Pump Bag Small

18" x 24", Small, Pond Pump Filter Bag, Goes Over The Entire..

$48.87 $53.00

Little Giant 566407 Waterfall and Stream Pump, 4, 280 GPH

Little Giant 566407 Waterfall and Stream Pump, 4, 280 GPH

Dual discharge waterfall pump4280 GPH capacity1-1/4-Inch fem..

$268.38 $357.00

Laguna Pressure Flo Clean 700 / 2500 Filter

Laguna Pressure Flo Clean 700 / 2500 Filter

PT1686 - Pressure Flo-Clean 700/2500 FilterThe unit can be i..

$257.45

Dynamic Head

The effect of the Earths gravity on the "lift" or head pressure is fairly simple; for every vertical foot of distance the pump moves the water you are adding one foot of head pressure so the ratio is a 1:1 ratio. The effects of the friction, caused by water as it travels through your hose or pipes, on the total head pressure is a little more difficult to calculate especially as there are slight variations in pipe friction in different hose materials and the smoothness of the inner bore. Basically. for every ten feet of pipe through which the water has to travel travel horizontally will contribute 1 foot of head height; the ratio of the pipe friction loss is a 10:1 ratio.

Plumbing fixtures and bends and corners in your hose also increase the total head you must calculate to ensure the proper final volume from your pump. Every corner with a 90 degree elbow in your plumbing will add 1 foot of head pressure  with a 1:1 ratio. 45 degree elbows, tees and even insert couplers can all have an impact on the final flow.

If you install a pump 40 feet away from the top of your waterfall which is 6 feet above the pump and the tubing is a single run of 40 feet horizontally then you add 4 feet of head for the tubing length (the 10:1 ratio) to the 6 foot differnetial between the pump location and the final height of the waterfall so your final total dynamic head calculation would be 10 feet. This means your final volume of water flow in this water feature or application would be the volume of flow on the performance curve that equaled the gallons per hour at 16 feet. This volume will certainly be much less than the initial volume the pump can move at an open flow or a zero head.

If in the above example your 40 feet of horizontal tubing run also required 3 elbows of 90 degrees then an additional 3 feet of theoretical head would be added and your final flow result would be at 19 feet on the performance curve of the pump. In this example you would want to choose a pump that has the desired GPH rating at 9 feet of head pressure.  Tubing size is also an important factor in accounting for head pressure loss, in general you should never reduce the diameter of the tubing below what the output size of the pump is, this will drastically increase head pressure, and reduce pump performance.  For maximum pump performance, using the largest tubing that is practical is the best choice. A best practice is to use a hose with an inner diameter that is the same as your pumps outlet fitting.